Automated Tablet Drop Magazine with temperature control before drop. All samples will be dropped simultaneously
Automated, simultaneous, tablet drop magazine; Samples are automatically dropped when temperature within the USP specified range. Staggered tablet drop is possible (manually)
Online OQ-Check for rpm by a second high precision sensor. Warning screen when rpm is out of tolerance. Documentation (connected to OQ Traffic Light)
Water Stabiliser with colour indicator, 1 bottle
Funnel with extension (plastics) for entering granules/powders and/or adding buffer solution through the sampling openings (Low-Head mode)
Prepared for upgrade to Sampling Station (without automated sampling station)
USP/EP/ JP compliant Sampling Station with automatic height adjustment of the 16 USP sampling heights. Teflon Tubing 1.6 mm o.d.
ditto, but with double filtration station for holding membrane filters
USP/EP/JP compliant Sampling Station with automatic height adjustment of the 16 USP sampling heights. Teflon Tubing 3.0 mm o.d.
ditto, but with double filtration station for holding membrane filters
8 additional electronic PT 100 temperature sensors for display and documentation of the media temperatures in all vessels, incl. automatic USP Sampling Station, Teflon tubing 1.6 mm o.d. (Low-Head, 1.000 ml only)
ditto, but with Teflon tubing 3.0
ditto, but with double filtration station for holding membrane filters
USP/EP/JP compliant Sampling Station with automatic Height Adjustment of the 16 USP sampling heights for connection with WATERS HPLC system (Luer connectors); including Double Filtration Station (by membrane filters)
TITANIUM sampling- and replacement probes (corrosion-free) instead of stainless steel probes, at additional cost
PEEK sampling- and replacement probes (absorptions-free) instead of stainless steel probes, at additional cost
Cleaning reservoir (acrylic glass) with 3 separate compartments for cleaning of all ERWEKA sampling stations. The 3 compartments eliminate any possibility of contamination
Electronic Calibration Kit for PT 100 temperature sensor/s. This kit allows fast calibration of the external electronic PT 100 temperature sensor as well as the 8 additional temperature sensors without the use of water. This not only eliminates the need of pre-heated water, it also saves up to 95% of the time needed
Spare Part Kits
Spare part kit comprising of 1 shaft, 1 vessel, 1 PT 100 temperature sensor, 1 belt, 2 fuses, 1 stirrer (please specify the type of Shaft System)
Spare part kit for DT 820 with automatic USP Sampling Station comprising of spare part kit 94-080-0001 and 1 belt, 2 st.steel sampling probes, 2 st.steel return probes and 8 tube connectors
Spare part kit for DT 820 with automatic USP Sampling Station and 8 temperature sensor option, incl. 94-080-0002
Vessel Centering Rings
Vessel-Centering- and –Down-Holding-Ring; for all kind of 1000 ml ERWEKA Vessels
Vessel-Centering- and –Down-Holding-Ring; for 1000 ml TAKAO Vessels
Vessel Support Plate
Vessel Support Plate (plastics) with bayonet openings for Vessel-Centering-Ring for ERWEKA Vessels; additional price
Vessel Support Plate (plastics) with bayonet openings for Vessel-Centering-Rings for TAKAO Vessels; additional price
Vessel Covers
V-Shaped vessel Covers made of plastic attached to the Drive-Head for automated Vessel covering in Low–Head operation
Low-Evaporation Vessel-Cover (1000 ml ERWEKA Vessel) for High-Head use; additional standard V-shaped Vessel-Cover
V-shaped Vessel-Cover for TAKAO Vessel, DELRIN, attached to the Drive-Head, for automated Vessel covering in Low-Head operation; additional price
Low-Evaporation Vessel-Cover (for 1000 ml TAKAO Vessel) for High-Head use
Paddles, Baskets, Discs for Paddle over Disc, Rotating Cylinder and Glassware please see Accessories.